{"id":3729,"date":"2026-11-26T12:13:23","date_gmt":"2026-11-26T04:13:23","guid":{"rendered":"https:\/\/www.dongnanswitches.com\/how-a-micro-switch-works"},"modified":"2026-11-26T12:25:26","modified_gmt":"2026-11-26T04:25:26","slug":"%d9%83%d9%8a%d9%81-%d9%8a%d8%b9%d9%85%d9%84-%d8%a7%d9%84%d9%85%d9%81%d8%aa%d8%a7%d8%ad-%d8%a7%d9%84%d8%af%d9%82%d9%8a%d9%82","status":"publish","type":"page","link":"https:\/\/www.dongnanswitches.com\/ar\/%d9%83%d9%8a%d9%81-%d9%8a%d8%b9%d9%85%d9%84-%d8%a7%d9%84%d9%85%d9%81%d8%aa%d8%a7%d8%ad-%d8%a7%d9%84%d8%af%d9%82%d9%8a%d9%82","title":{"rendered":"\u0643\u064a\u0641 \u064a\u0639\u0645\u0644 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062f\u0642\u064a\u0642: \u0627\u0644\u0622\u0644\u064a\u0629\u060c \u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u060c \u0648\u0627\u0644\u0639\u0645\u0631 \u0627\u0644\u0627\u0641\u062a\u0631\u0627\u0636\u064a."},"content":{"rendered":"<nav class=\"dn-toc\" aria-label=\"On this page\">\n<p class=\"dn-toc-title\">On this page<\/p>\n<ol>\n<li><a href=\"#mechanism\">The snap-action mechanism<\/a><\/li>\n<li><a href=\"#parts\">The five parts inside the housing<\/a><\/li>\n<li><a href=\"#terminals\">COM, NO and NC explained<\/a><\/li>\n<li><a href=\"#force\">Operating force and travel: OF, RF, PT, OT<\/a><\/li>\n<li><a href=\"#contacts\">Contact materials and what they are for<\/a><\/li>\n<li><a href=\"#bounce\">Bounce, arcing and why the snap matters<\/a><\/li>\n<li><a href=\"#life\">What limits the life of a micro switch<\/a><\/li>\n<li><a href=\"#diagram\">How to read a micro switch datasheet<\/a><\/li>\n<li><a href=\"#faq\">Frequently asked questions<\/a><\/li>\n<\/ol>\n<\/nav>\n<h2 id=\"mechanism\">The snap-action mechanism<\/h2>\n<p>Inside the switch there is a spring blade held in a curve between two supports. When the actuator pushes the blade, the curve flattens slightly and the spring stores energy. At a specific point \u2014 the tipping point \u2014 the blade&#8217;s curvature reverses and it snaps to the other side, carrying the moving contact with it.<\/p>\n<p>Two consequences follow. First, the transition is fast: a few milliseconds, regardless of how slowly the actuator moves. Second, the switching point is repeatable: it depends on the spring geometry, not on the speed of the actuator, so the same part trips at the same position every time.<\/p>\n<p>The alternative \u2014 a sliding or wiping contact \u2014 moves slowly through the transition, which produces a long arc, more erosion and a less repeatable trip point. Snap action is why a micro switch can survive a million mechanical cycles in a washing machine lid.<\/p>\n<h2 id=\"parts\">The five parts inside the housing<\/h2>\n<table>\n<thead>\n<tr>\n<th>Part<\/th>\n<th>Function<\/th>\n<th>Typical material<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Actuator<\/td>\n<td>Transmits the external movement to the spring blade<\/td>\n<td>POM, PBT, stainless steel for levers<\/td>\n<\/tr>\n<tr>\n<td>Spring blade<\/td>\n<td>Stores and releases the snap energy; carries the moving contact<\/td>\n<td>Beryllium copper or stainless spring steel<\/td>\n<\/tr>\n<tr>\n<td>Moving contact<\/td>\n<td>The contact that changes position<\/td>\n<td>Silver alloy, silver-nickel, gold-plated for low level<\/td>\n<\/tr>\n<tr>\n<td>Fixed terminals<\/td>\n<td>Stationary contacts and the external connection points<\/td>\n<td>Brass, copper alloy, silver-plated<\/td>\n<\/tr>\n<tr>\n<td>Housing<\/td>\n<td>Holds the contact gap, insulates, seals<\/td>\n<td>PBT, PA66, PPS; flame class UL94 V-0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The contact gap is the distance between the open contacts. It is set by the housing and the blade geometry, and it determines the switch&#8217;s ability to break a given voltage. It cannot be adjusted in the field, and it is the first thing that changes if a housing is distorted by heat or over-tightened mounting screws.<\/p>\n<h2 id=\"terminals\">COM, NO and NC explained<\/h2>\n<p>In an SPDT switch there are three terminals:<\/p>\n<ul>\n<li><strong>COM<\/strong> \u2014 the common terminal, connected to the moving contact.<\/li>\n<li><strong>NC<\/strong> \u2014 normally closed: connected to COM when the actuator is at rest. Pressing the actuator opens this circuit.<\/li>\n<li><strong>NO<\/strong> \u2014 normally open: disconnected from COM at rest. Pressing the actuator closes this circuit.<\/li>\n<\/ul>\n<p>The naming describes the unactuated state, not the &#8220;off&#8221; state. In a door interlock, the NC contact carries power while the door is closed; opening the door releases the actuator and the NC contact opens, cutting power. That is why NC is the safety contact \u2014 a broken wire or a failed spring looks the same as an open door.<\/p>\n<h2 id=\"force\">Operating force and travel: OF, RF, PT, OT<\/h2>\n<p>Four numbers describe the mechanical behaviour, and they appear on every proper datasheet:<\/p>\n<table>\n<thead>\n<tr>\n<th>Symbol<\/th>\n<th>Name<\/th>\n<th>Meaning<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>OF<\/td>\n<td>\u0642\u0648\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>Force needed at the actuator to trip the switch<\/td>\n<\/tr>\n<tr>\n<td>RF<\/td>\n<td>Release force<\/td>\n<td>Force at which the switch returns to its rest state<\/td>\n<\/tr>\n<tr>\n<td>PT<\/td>\n<td>Pre-travel<\/td>\n<td>Movement from rest position to the trip point<\/td>\n<\/tr>\n<tr>\n<td>OT<\/td>\n<td>Over-travel<\/td>\n<td>Movement available after the trip point before the actuator bottoms out<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>RF is always lower than OF; the difference is the hysteresis that prevents chatter. OT is the margin your mechanism needs \u2014 a design that stops exactly at the trip point will fail as soon as tolerances stack up.<\/p>\n<h2 id=\"contacts\">Contact materials and what they are for<\/h2>\n<ul>\n<li><strong>Silver alloy (AgNi, AgCdO)<\/strong> \u2014 the general-purpose choice for power switching, resistant to welding at moderate currents.<\/li>\n<li><strong>Silver with gold plating<\/strong> \u2014 for low-level, dry-circuit signals where the current is too small to break through an oxide film.<\/li>\n<li><strong>Gold alloy<\/strong> \u2014 for very low currents in corrosive atmospheres, and for signal contacts that must not oxidise during long idle periods.<\/li>\n<\/ul>\n<p>Using a gold-contact switch on a 10 A motor load is a mistake in the opposite direction: the gold is destroyed by the arc and the contact degrades faster than a plain silver one. Match the contact to the load.<\/p>\n<h2 id=\"bounce\">Bounce, arcing and why the snap matters<\/h2>\n<p>When contacts close, they bounce for a fraction of a millisecond \u2014 several make-and-break events before settling. For a lamp or motor, invisible. For a logic input counting pulses, it produces multiple counts.<\/p>\n<p>The snap action reduces the time contacts spend close together, which reduces arcing. Arcing is what erodes the silver and eventually welds the contacts. Slow, wiping transitions \u2014 or a mechanism that holds the actuator at the trip point \u2014 produce long arcs and short life.<\/p>\n<p>For logic-level signals, debounce in software or add an RC filter. For power loads, choose a switch with margin on the inrush current rather than relying on the snap alone.<\/p>\n<h2 id=\"life\">What limits the life of a micro switch<\/h2>\n<p>Three failure modes dominate:<\/p>\n<ol>\n<li><strong>Contact erosion.<\/strong> The arc removes silver from the contact face until the gap grows or the contact welds. This is why electrical life is rated separately and is much lower than mechanical life.<\/li>\n<li><strong>Spring fatigue.<\/strong> The blade loses force over millions of cycles, and OF drifts below the mechanism&#8217;s capability. High temperature accelerates this.<\/li>\n<li><strong>Seal and housing ageing.<\/strong> Elastomer seals harden, housings creep, and moisture enters. In sealed switches this is often the real end of life, not the contacts.<\/li>\n<\/ol>\n<h2 id=\"diagram\">How to read a micro switch datasheet<\/h2>\n<p>A complete datasheet gives you: contact configuration, rated current and voltage for AC and DC separately, contact resistance, insulation resistance, dielectric withstand voltage, operating force and travel, mechanical and electrical life, operating temperature, IP rating, terminal type, and approvals. If any of those is missing, ask for it \u2014 a datasheet without a DC rating or a life figure is a marketing sheet, not an engineering document.<\/p>\n<p>For a worked example of choosing between parts using these numbers, see the <a href=\"https:\/\/www.dongnanswitches.com\/ar\/%d8%af%d9%84%d9%8a%d9%84-%d8%a7%d8%ae%d8%aa%d9%8a%d8%a7%d8%b1-%d8%a7%d9%84%d9%85%d9%81%d8%aa%d8%a7%d8%ad-%d8%a7%d9%84%d8%af%d9%82%d9%8a%d9%82\/\">\u062f\u0644\u064a\u0644 \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062f\u0642\u064a\u0642.<\/a>. To compare the device types, see <a href=\"https:\/\/www.dongnanswitches.com\/ar\/%d9%85%d9%81%d8%aa%d8%a7%d8%ad-%d8%b5%d8%ba%d9%8a%d8%b1-%d9%85%d9%82%d8%a7%d8%a8%d9%84-%d9%85%d9%81%d8%aa%d8%a7%d8%ad-%d8%ad%d8%af%d9%88%d8%af%d9%8a\/\">\u0645\u0641\u062a\u0627\u062d \u0635\u063a\u064a\u0631 \u0645\u0642\u0627\u0628\u0644 \u0645\u0641\u062a\u0627\u062d \u062d\u062f\u0648\u062f\u064a.<\/a>.<\/p>\n<h2 id=\"faq\">Frequently asked questions<\/h2>\n<div class=\"dn-faq\">\n<details>\n<summary>\u0644\u0645\u0627\u0630\u0627 \u064a\u0635\u062f\u0631 \u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062f\u0642\u064a\u0642 \u0635\u0648\u062a\u064b\u0627 \u0643\u0627\u0644\u0646\u0642\u0631\u061f<\/summary>\n<p>\u0627\u0644\u0636\u063a\u0637 \u0647\u0648 \u0639\u0646\u062f\u0645\u0627 \u062a\u0646\u0642\u0636\u0628 \u0634\u0641\u0631\u0629 \u0627\u0644\u0631\u0628\u064a\u0639 \u0645\u0646 \u062e\u0644\u0627\u0644 \u0645\u0648\u0642\u0639\u0647\u0627 \u063a\u064a\u0631 \u0627\u0644\u0645\u0633\u062a\u0642\u0631 \u0648\u062a\u062a\u0635\u0627\u062f\u0645 \u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644. \u0625\u0646\u0647\u0627 \u0627\u0644\u0639\u0644\u0627\u0645\u0629 \u0627\u0644\u0635\u0648\u062a\u064a\u0629 \u0644\u0644\u0639\u0645\u0644 \u0627\u0644\u0633\u0631\u064a\u0639 \u0648\u0641\u062d\u0635 \u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0641\u064a\u062f - \u0641\u0627\u0644\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0630\u064a \u0644\u0627 \u064a\u0635\u062f\u0631 \u0623\u064a \u0636\u063a\u0637 \u0625\u0645\u0627 \u0623\u0646\u0647 \u0644\u0627 \u064a\u062a\u0645 \u062a\u0634\u063a\u064a\u0644\u0647 \u0623\u0648 \u0623\u0646\u0647 \u062a\u0627\u0644\u0641.<\/p>\n<\/details>\n<details>\n<summary>What is the difference between a micro switch and a tactile switch?<\/summary>\n<p>A tactile switch is a momentary push button with a dome or membrane, designed for user input on a PCB and usually rated for very low currents. A micro switch is a snap-action switch designed to switch real loads and to be actuated by a mechanism, not a finger.<\/p>\n<\/details>\n<details>\n<summary>Can a micro switch be used as a push button?<\/summary>\n<p>Yes, and many are \u2014 the difference is in the actuator and the mounting. A push button switch has a plunger or cap designed for finger actuation and a panel mounting; a micro switch has a small actuator designed to be driven by a mechanism.<\/p>\n<\/details>\n<details>\n<summary>Do micro switches work in both directions?<\/summary>\n<p>The switch itself trips in one direction of actuator travel. A mechanism can actuate it from either side, but the trip point and force are defined for the specified direction. If you need bidirectional detection, use two switches or a different mechanism.<\/p>\n<\/details>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>On this page The snap-action mechanism The five parts inside the housing COM, NO and NC explained Operating force and travel: OF, RF, PT, OT Contact materials and what they are for Bounce, arcing and why the snap matters What limits the life of a micro switch How to read a micro switch datasheet Frequently [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-geo-guide.php","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3729","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.dongnanswitches.com\/ar\/wp-json\/wp\/v2\/pages\/3729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dongnanswitches.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dongnanswitches.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dongnanswitches.com\/ar\/wp-json\/wp\/v2\/comments?post=3729"}],"version-history":[{"count":1,"href":"https:\/\/www.dongnanswitches.com\/ar\/wp-json\/wp\/v2\/pages\/3729\/revisions"}],"predecessor-version":[{"id":3733,"href":"https:\/\/www.dongnanswitches.com\/ar\/wp-json\/wp\/v2\/pages\/3729\/revisions\/3733"}],"wp:attachment":[{"href":"https:\/\/www.dongnanswitches.com\/ar\/wp-json\/wp\/v2\/media?parent=3729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}