{"id":3739,"date":"2026-11-26T14:56:36","date_gmt":"2026-11-26T06:56:36","guid":{"rendered":"https:\/\/www.dongnanswitches.com\/no-vs-nc-micro-switch"},"modified":"2026-11-26T14:56:36","modified_gmt":"2026-11-26T06:56:36","slug":"interruptor-micro-no-vs-nc","status":"publish","type":"page","link":"https:\/\/www.dongnanswitches.com\/es\/interruptor-micro-no-vs-nc","title":{"rendered":"Interruptor micro NO vs NC: \u00bfCu\u00e1l es la diferencia?"},"content":{"rendered":"<nav class=\"dn-toc\" aria-label=\"On this page\">\n<p class=\"dn-toc-title\">On this page<\/p>\n<ol>\n<li><a href=\"#definition\">What normally open and normally closed mean<\/a><\/li>\n<li><a href=\"#truth\">The truth table<\/a><\/li>\n<li><a href=\"#safety\">Why safety circuits use NC<\/a><\/li>\n<li><a href=\"#circuits\">Typical circuits for each<\/a><\/li>\n<li><a href=\"#test\">How to tell which one you have<\/a><\/li>\n<li><a href=\"#choose\">How to choose<\/a><\/li>\n<li><a href=\"#faq\">Frequently asked questions<\/a><\/li>\n<\/ol>\n<\/nav>\n<h2 id=\"definition\">What normally open and normally closed mean<\/h2>\n<p>A micro switch has a moving contact and two fixed contacts. In the unactuated state \u2014 nothing pressing the plunger \u2014 the moving contact rests against one of them:<\/p>\n<ul>\n<li><strong>Normally open (NO)<\/strong>: the circuit through that contact is broken at rest. Pressing the actuator closes it.<\/li>\n<li><strong>Normally closed (NC)<\/strong>: the circuit is complete at rest. Pressing the actuator breaks it.<\/li>\n<\/ul>\n<p>&#8220;Normal&#8221; here means mechanical rest, not electrical off. A switch mounted in a closed door is being held actuated all day, so its rest state is the door-open state. Always ask &#8220;rest with respect to what?&#8221; before designing around the term.<\/p>\n<h2 id=\"truth\">The truth table<\/h2>\n<table>\n<thead>\n<tr>\n<th>State<\/th>\n<th>COM\u2013NO<\/th>\n<th>COM\u2013NC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Actuator at rest<\/td>\n<td>Open<\/td>\n<td>Closed<\/td>\n<\/tr>\n<tr>\n<td>Actuator pressed<\/td>\n<td>Closed<\/td>\n<td>Open<\/td>\n<\/tr>\n<tr>\n<td>Actuator released<\/td>\n<td>Open<\/td>\n<td>Closed<\/td>\n<\/tr>\n<tr>\n<td>Broken wire or failed spring<\/td>\n<td>Open<\/td>\n<td>Open<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The last row is the one that matters for safety: both contacts end up open when the switch or its wiring fails. Only the NC contact fails in the safe direction for a circuit that is supposed to be closed.<\/p>\n<h2 id=\"safety\">Why safety circuits use NC<\/h2>\n<p>Take a machine guard. The circuit that powers the motor runs through the switch. If the switch uses NO, the motor runs only while the guard is closed and the switch is pressed \u2014 sounds correct, but a severed wire or a broken spring also makes the contact open, which stops the motor. Actually that is safe. Now invert the logic: an emergency stop button wired NO would only work while the circuit is intact; a broken wire means pressing it does nothing.<\/p>\n<p>The rule is simpler than the reasoning: <strong>the safe state should be the unpowered, de-energised, open-circuit state, and the switch should have to be actively held in the other state.<\/strong> That is why emergency stops, door interlocks and guard switches use NC contacts: loss of power, a broken wire or a worn switch all produce a stop, which is the safe outcome. NO contacts are for signals and start commands, where a failure to detect is annoying rather than dangerous.<\/p>\n<h2 id=\"circuits\">Typical circuits for each<\/h2>\n<table>\n<thead>\n<tr>\n<th>Solicitud<\/th>\n<th>Contacto<\/th>\n<th>Reason<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Door interlock (power cut when open)<\/td>\n<td>NC<\/td>\n<td>Broken wire stops the machine<\/td>\n<\/tr>\n<tr>\n<td>Emergency stop<\/td>\n<td>NC<\/td>\n<td>Fail-safe by design<\/td>\n<\/tr>\n<tr>\n<td>Presence \/ position detection<\/td>\n<td>NO<\/td>\n<td>Signal only; a false negative stops nothing<\/td>\n<\/tr>\n<tr>\n<td>Start button<\/td>\n<td>NO<\/td>\n<td>Momentary command<\/td>\n<\/tr>\n<tr>\n<td>Limit switch on a moving axis<\/td>\n<td>NC (typically)<\/td>\n<td>Loss of signal stops motion<\/td>\n<\/tr>\n<tr>\n<td>Coin or card detection<\/td>\n<td>NO<\/td>\n<td>Event counting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Most micro switches are SPDT, which gives you both contacts in one part. Use NC for the safety path and NO for the status signal \u2014 that is why SPDT is the default configuration rather than SPST.<\/p>\n<h2 id=\"test\">How to tell which one you have<\/h2>\n<p>With a multimeter in continuity mode and the switch disconnected:<\/p>\n<ol>\n<li>At rest, the beeping pair is COM and NC.<\/li>\n<li>Press the actuator; the beeping pair becomes COM and NO.<\/li>\n<li>The terminal in both pairs is COM.<\/li>\n<\/ol>\n<p>If the switch is already wired into a machine, disconnect power first and test at the terminals. A reading that changes when you press the actuator confirms the contact is working; a reading that stays closed confirms you are on NC.<\/p>\n<h2 id=\"choose\">How to choose<\/h2>\n<ul>\n<li><strong>Ask what happens when the switch fails.<\/strong> If the answer must be &#8220;the machine stops&#8221;, use NC.<\/li>\n<li><strong>Ask what happens when a wire breaks.<\/strong> Same rule: NC if the failure must be safe.<\/li>\n<li><strong>Use SPDT<\/strong> when you need both a safety contact and a status signal, which is most of the time.<\/li>\n<li><strong>Do not mix logic.<\/strong> A controller that reads NC as &#8220;door closed&#8221; will invert the meaning of every downstream diagnostic; document the convention.<\/li>\n<\/ul>\n<p>For terminal identification and wiring examples, see <a href=\"\/es\/diagrama-de-cableado-del-interruptor-micro\/\">micro switch wiring diagrams<\/a>. For part selection, see the <a href=\"\/es\/guia-de-seleccion-de-micro-interruptores\/\">Gu\u00eda de selecci\u00f3n de micro interruptores.<\/a>.<\/p>\n<h2 id=\"faq\">Frequently asked questions<\/h2>\n<div class=\"dn-faq\">\n<details>\n<summary>\u00bfQu\u00e9 significa \"normalmente abierto\" en un micro interruptor?<\/summary>\n<p>El circuito entre el terminal com\u00fan y el NO se interrumpe cuando el actuador est\u00e1 en reposo, y se cierra cuando se presiona el actuador. Es el contacto utilizado para los comandos de inicio y las se\u00f1ales de detecci\u00f3n.<\/p>\n<\/details>\n<details>\n<summary>What does normally closed mean?<\/summary>\n<p>The circuit between common and the NC terminal is complete at rest and opens when the actuator is pressed. It is the contact used where a broken wire or a failed switch must stop the machine.<\/p>\n<\/details>\n<details>\n<summary>Can I use NO instead of NC for a door switch?<\/summary>\n<p>Only if the door switch is purely a status signal. For a safety interlock that must cut power, NC is required, because an NO contact cannot distinguish &#8220;door closed&#8221; from &#8220;wire broken&#8221;.<\/p>\n<\/details>\n<details>\n<summary>How can I tell NO from NC without a meter?<\/summary>\n<p>Look for the moulded markings COM, NO and NC on the housing. If they are worn off, the terminal layout is not reliable evidence \u2014 use a multimeter.<\/p>\n<\/details>\n<details>\n<summary>Is SPDT normally open or normally closed?<\/summary>\n<p>Both. An SPDT switch has one common terminal and two fixed contacts, so it provides an NO and an NC contact in the same part.<\/p>\n<\/details>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>On this page What normally open and normally closed mean The truth table Why safety circuits use NC Typical circuits for each How to tell which one you have How to choose Frequently asked questions What normally open and normally closed mean A micro switch has a moving contact and two fixed contacts. In the [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-geo-guide.php","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3739","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.dongnanswitches.com\/es\/wp-json\/wp\/v2\/pages\/3739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dongnanswitches.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dongnanswitches.com\/es\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dongnanswitches.com\/es\/wp-json\/wp\/v2\/comments?post=3739"}],"version-history":[{"count":0,"href":"https:\/\/www.dongnanswitches.com\/es\/wp-json\/wp\/v2\/pages\/3739\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.dongnanswitches.com\/es\/wp-json\/wp\/v2\/media?parent=3739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}